Skip to content
VISIONTECHNIK

3D laser profilers for profile and height measurement

3D laser profilers project a laser line onto the part and view it from a fixed angle. From the position of the line in the image, the sensor computes the height of every point along the line (triangulation); as the part passes under the sensor, the profiles add up to a 3D surface. This category holds the DP2000, DP3000 and DP4000 series from HIKROBOT with reference distances from 21.4 mm to 947.5 mm, Z measurement ranges from 5.2 mm to 910 mm and measuring field widths at the reference distance from 14 mm to 515 mm. The DP2000 and DP3000 measure 3200 points per profile, the DP4000 4080 points. All models use Gigabit Ethernet and 24 VDC, are rated IP67 and have laser class 2, 3R or 3B depending on the model.

48 products

No obligation · we usually reply within 24 hours on business days

Reference distance
Z measuring range
Field of view at reference distance
Z repeatability
Scan rate
Profile points
Laser class

Products

Choosing a 3D laser profiler

Measurement range and reference distance

Three values describe the measuring volume. The reference distance is the working distance between the near and far limits that the data refers to. The Z measurement range is the measurable height, the X measurement range the width of the laser line. The width grows from the near to the far limit: on the MV-DP2470-01P from 142 mm through 315 mm at the reference distance to 488 mm, on the MV-DP2020-01P only from 14 mm to 14.6 mm.

The number in the model name is not the reference distance. The MV-DP2470-01P works at 565 mm, the MV-DP2580-01P at 585 mm, the MV-DP2900-03P at 925 mm. Always compare against the technical data.

Z resolution and point spacing change across the measurement range and are therefore given as a span. The point spacing along the profile follows from the line width and the number of profile points: 4.38 µm to 4.67 µm on the MV-DP2020-01P, 76.5 µm to 250.1 µm on the MV-DP2900-03P. HIKROBOT states the Z linearity of all models as ±0.01% of the measurement range.

DP2000, DP3000 and DP4000 compared

The series differ mainly in profile points, profile rate and connection:

  • DP2000: 3200 profile points, 1.7 kHz to 23.9 kHz in high frame rate mode (from 3.3 kHz on the MV-DP2050, MV-DP2061, MV-DP2080 and MV-DP2140), reference distance 21.4 mm to 925 mm, typically 15.1 W to 15.2 W
  • DP3000: 3200 profile points, 3.4 kHz to 46.7 kHz in high frame rate mode (from 6.4 kHz on the MV-DP3050, MV-DP3061, MV-DP3080 and MV-DP3140), reference distance 21.4 mm to 947.5 mm, typically 15.1 W to 17.2 W; HIKROBOT lists single-frame HDR for the series
  • DP4000: 4080 profile points, 2.5 kHz across the full measurement range and up to 49 kHz in ROI mode, reference distance 22.6 mm to 940 mm, additional RS-232 on the M12 connector, typically 20 W to 20.6 W

Many sensor heads exist in both DP2000 and DP3000 with the same geometry, such as the MV-DP2020-01P and MV-DP3020-01P with 21.4 mm reference distance, 6.8 mm Z measurement range and 0.22 µm repeatability. The difference then lies in profile rate and power consumption. For the MV-DP2060/3060, MV-DP2120/3120 and MV-DP2900/3900, reference distance and measurement range differ as well.

Profile rate and conveyor speed

The profile rate determines how densely the profiles lie in the direction of motion: the profile spacing equals the speed divided by the profile rate. At 200 mm/s and 2 kHz, the profiles are 0.1 mm apart, and the same applies at 1 m/s and 10 kHz.

HIKROBOT states the rate in different ways: for the DP2000 and DP3000 as a span in high frame rate mode, for the DP4000 as the rate across the full measurement range and as the maximum in ROI mode. Evaluating only part of the measurement range raises the rate. Only values from the same operating mode are comparable, and the required rate follows from the smallest feature in the direction of motion.

Triggering is by software or by a rotary encoder with a differential signal. This keeps the profile spacing constant even when the belt speed changes.

Laser class, wavelength and safety measures

In all manufacturer tables, the -01P suffix stands for a blue laser at 405 nm and the -03P suffix for a red laser at 650 nm or 660 nm. Which wavelength gives the more even profile on a surface depends on material and finish and can only be judged reliably on the real part.

The laser class is listed per model in the technical data. The MV-DP4060-01P is class 2. The MV-DP2061-01P, MV-DP2062-01P, MV-DP2470-01P, MV-DP2580-01P, MV-DP3060-03P, MV-DP3061-01P, MV-DP3062-01P, MV-DP3470-01P, MV-DP3580-01P and MV-DP4020-01P are class 3B, all other models class 3R.

With class 3R, direct viewing of the beam is potentially hazardous; with class 3B, specular reflections are hazardous too. For both classes, additional laser safety measures under occupational safety rules must be planned at the installation site. Typical measures are shielding the beam path, marking the laser area and avoiding reflective surfaces; the operator's risk assessment is decisive.

Mounting, connection and environment

All laser profilers are rated IP67 and operate at 0 °C to 45 °C, the MV-DP2023-01P and MV-DP3023-01P at 0 °C to 40 °C, each at 20% to 85% relative humidity without condensation. They weigh approx. 750 g to 1780 g; the MV-DP4940-03P has the longest housing at 302.5 mm.

Data runs over Gigabit Ethernet (1000 Mbit/s, compatible with 100 Mbit/s). Power and inputs and outputs share a 12-pin M12 connector, on the MV-DP2023-01P and MV-DP3023-01P a 17-pin one. The supply voltage is 24 VDC.

The output comprises profile data, depth image and brightness image, on some models also the original image. As client software, HIKROBOT names 3DMVS, on most models also VM3D or third-party software, under Windows 7, 10 or 11. A computer with at least 8 GB of memory and an i5 CPU is recommended.

Frequently asked questions about 3D laser profilers

What does the reference distance mean?
It is the working distance that the measuring field and the specifications refer to, and it lies between the near and far limits of the Z measurement range. For the models in this category, it ranges from 21.4 mm to 947.5 mm. The number in the model name is not the reference distance; the MV-DP2470-01P, for example, works at 565 mm.
How do the DP2000, DP3000 and DP4000 differ?
The DP2000 and DP3000 measure 3200 points per profile, the DP4000 4080 points. In high frame rate mode, the DP2000 reaches up to 23.9 kHz and the DP3000 up to 46.7 kHz; the DP4000 achieves 2.5 kHz across the full measurement range and up to 49 kHz in ROI mode and adds RS-232 on the M12 connector. Many DP2000 and DP3000 sensor heads share the same geometry and then differ in profile rate and power consumption.
How fast may the part move?
That depends on the profile spacing you need: speed divided by profile rate. A 0.1 mm profile spacing at 500 mm/s requires 5 kHz. Because the achievable rate depends on operating mode and evaluated window, we check it for the specific model and the measurement range required.
Which laser class do the laser profilers have?
The MV-DP4060-01P is class 2, individual models are class 3B, all others class 3R. The class is listed in the technical data of every model. From class 3R upward, additional laser safety measures under occupational safety rules must be planned at the installation site.

Next technical step

Still unsure which model fits?

Tell us the size, height differences and surface of the part, the smallest structure to be measured, the conveyor speed and the available mounting distance. We compare reference distance, measurement range, profile rate and laser class of the suitable models against the manufacturer data and say openly what still needs clarifying before a decision.

Request a laser profiler